Introducción a el método de limpieza microscopio ocular

 


Microscopio ocular limpieza:


1. Blow off the dust with the ear cleaning ball


2. Aplicar puro alcohol (100 porcentual ) a a fibra-larga algodón hisopo. Long fibras son usados para prevenir corto algodón fibras de restante en microscopio lentes o protectores filtros de digitales cámaras. El propósito de 100 porcentual puro alcohol es a evitar dejar agua marcas después limpiar.


3. Shake off the excess liquid (the purpose is to avoid too much liquid remaining on the surface of the lens).


4. Take the center of the lens as the center of the circle, and push the dirt to the edge of the lens in a circular direction.


5. Si tuya encuentra cualquier sucio manchas que no puede ser eliminado, por favor contacto el ingeniero. El ingeniero voluntad tomar medidas acorde a la situación a evitar pérdida de recubrimiento.



Cómo para Ajustar el Microscopio


1. Luz fuente filamento ajuste: El viejo microscopio necesidades para ajustar la posición de la bombilla. La luz fuente de hoy's más nuevo microscopios es ya precentrado, so no ajuste es requerido.


2. Adjustment of the center of the condenser: in fact, the focus of the adjustment of the optical axis of the microscope is the adjustment of the position of the condenser.
First, shrink the field diaphragm and observe with a 10X objective lens. The outline of the field diaphragm can be seen in the field of view. If it is not in the center, use the two adjustment screws on the outside of the condenser to adjust it to the central part. When the field diaphragm is slowly increased, you can see that the beam spreads evenly to the periphery of the field of view until the contour image of the field diaphragm is completely inscribed with the edge of the field of view, indicating that it has been aligned with the axis. Then slightly increase the field diaphragm, so that the contour image is just outside the field of view or slightly larger.


3. Ajuste de la apertura diafragma: La apertura diafragma es instalado en el condensador. Hay es departamento números y posicionamiento marcas en el exterior borde de el condensador de el investigación microscopio, que es conveniente para ajustar el número apertura de el condensador y el objetivo lente. In principio, el numérico apertura de el condensador necesita a ser ajustado cuando reemplazar el objetivo lente. Generalmente, el numérico apertura de el objetivo lente multiplicado por 0.6 o 0.8 is el numérico apertura de el condensador.

 